Importing medical devices and supplies: SFDA requirements

Importing medical devices into Saudi Arabia for sale requires the device to hold a Medical Device Marketing Authorization (MDMA) from the SFDA, the importer to hold a valid establishment licence, the manufacturer to have a licensed authorized representative, and a shipment release approval obtained through SFDA’s system and FASAH before or on arrival.

Who regulates medical device imports in Saudi Arabia?

The regulator is the Saudi Food and Drug Authority (SFDA), through its Medical Devices Sector, under the Medical Devices Law and its Implementing Regulation. SFDA has published “Requirements on Importation and Shipments Clearance of Medical Devices” (MDS-REQ5), which sets out what is needed for each import purpose: commercial circulation, local manufacturing, clinical studies, research and education, demonstration, national emergencies, humanitarian use and personal use.

Customs (ZATCA) handles the declaration, duties and inspection through FASAH, but will not release a medical shipment until SFDA has approved it. So importing medical devices into Saudi Arabia runs on two parallel tracks: a regulatory track with SFDA and a customs track with your broker. For the customs side, see Saudi import clearance via FASAH.

Tip: MDS-REQ5 does not cover medical device spare parts, medical imaging materials or radioactive materials; these have separate requirements. If you are unsure whether your product is a medical device at all, SFDA offers a product classification service to determine which regime applies.

Which licences do you need to import medical devices for sale?

Under SFDA’s requirements, importing devices for circulation depends on several elements that should be in place before the goods are shipped:

RequirementWho holds itWhat it means in practice
Medical Device Marketing Authorization (MDMA)Manufacturer, via its authorized representativeNo release for sale without a valid MDMA; accessories must be listed in the MDMA with a national listing number
Importer licence (establishment licence)ImporterA valid medical device establishment licence covering import activity
Authorized representative (AR) licenceManufacturer’s representative in KSAVerified automatically in the release application
Importation licence/permissionImporterOnly in specific cases, e.g. chemicals classified as medical devices including some IVDs; applied for via GHAD
Shipment release approvalImporter or its agentFiled via SFDA’s Faseh Services system and the FASAH platform; can be filed before the shipment arrives

Refurbished devices need an MDMA after refurbishment in addition to the original one. Used devices are prohibited except in specific cases covered below.

Which documents are needed to clear a medical device shipment?

SFDA lists the documents required for shipment clearance. The main ones are:

  1. Purchase invoice authenticated by the chamber of commerce in the country of origin, showing invoice number, manufacturer, product name, quantity and unit price. Model/part numbers and lot/serial numbers must appear on the invoice or packing list.
  2. Bill of lading.
  3. Customs declaration.
  4. MDMA for devices imported for circulation, which must be valid.
  5. Declaration of conformity of the shipment to the Medical Devices Law and its Implementing Regulation, using SFDA’s template. This is different from the declaration submitted to obtain the MDMA.

The importer and AR licences are checked automatically. If the shipment needs a temperature data logger under the manufacturer’s instructions, its serial number must appear on a shipping document such as the invoice or bill of lading. For general document guidance, see documents required for import and export.

What are the shelf-life, storage and labelling rules on arrival?

These are among the most common reasons for rejection, and SFDA spells them out in its shipment procedures annex:

  • Remaining shelf life: if total shelf life is under one year, at least 40% must remain at the port of entry; if it is over one year, at least seven months must remain.
  • Storage and transport: follow the manufacturer’s instructions; where specific temperature or humidity is required, each parcel needs an electronic data logger, activated from shipment and readable at the port without special software.
  • Labelling: must meet SFDA requirements and match the labelling previously submitted to SFDA.

Tip: Calculate remaining shelf life against the expected arrival date at the port, not the ship date. A sea shipment that takes weeks can arrive below the threshold and be rejected even though it was compliant when it left the factory.

Which medical devices are prohibited from import?

SFDA’s requirements prohibit several categories, including:

  • Used medical devices, unless imported for maintenance or refurbishment in KSA and re-export, or returning to KSA after maintenance, calibration, display or testing abroad.
  • Powdered surgical and examination gloves, and absorbable powder used to help put gloves on.
  • Products labelled as intended for another market, such as “For sale only in US”.
  • Electrical devices designed for a supply other than 230 or 400 volts, a frequency other than 60 Hz, or fitted with plugs not compatible with the Saudi Building Code or the Saudi plug standard.
  • Any device SFDA considers may endanger patients or users, even if it holds an MDMA.

For prohibited and restricted goods more broadly, read prohibited and restricted imports in Saudi Arabia.

What are the steps from order to release?

  1. Confirm the status: is the product a medical device, what class, and does it hold a valid MDMA in the manufacturer’s name?
  2. Prepare your licences: a valid importer licence, and confirmation from the manufacturer or SFDA that the device has a licensed AR.
  3. Agree documents with the supplier: an authenticated invoice with the required detail, lot and serial numbers, compliant labels, and a data logger where needed.
  4. File the release application through SFDA’s system and FASAH, ideally before arrival to cut port time.
  5. Customs declaration: filed by your broker on FASAH, with any duty and import VAT paid.
  6. Inspection and sampling: SFDA may draw random samples for evaluation and does not bear the cost of the samples or testing.
  7. Decision: release, conditional release with notes to correct, or rejection. The importer may object within 60 days of rejection using SFDA’s published objection procedure.

The ports of entry listed in SFDA’s requirements include Jeddah Islamic Port, King Abdullah Port in Rabigh and King Abdulaziz International Airport in Jeddah, which are the ports where Fares Customs Clearance works every day.

Can you import a medical device for personal use?

Yes, through a separate route. Under SFDA’s requirements, the device should be for home use by lay persons, and quantities are limited: one shipment should not exceed three months of use, and no more than five shipments per calendar year, unless justified by a medical report. The application is filed via GHAD with the required declaration and device information, and release approval is then requested when the item ships. Such devices may not be used commercially.

What mistakes delay medical device clearance?

  • Shipping before checking that the MDMA and importer licence are valid.
  • An invoice that is not authenticated or lacks lot and serial numbers.
  • Remaining shelf life below the threshold on arrival.
  • Labels marked for another market or different from the approved labels.
  • No data logger for sensitive products, or its serial number missing from the documents.
  • Mixing spare parts and devices in one shipment without clear separation on the invoice.

Review documents with your broker before shipping. You can estimate duty and VAT with our calculator, or contact us to review your shipment file.

Tip: This summary is based on SFDA’s published importation and shipment clearance requirements, which SFDA updates periodically. Keep the originals of documents submitted to SFDA for five years from clearance, as required, and check the latest version before each shipment.

Frequently asked questions

What is an MDMA?

A Medical Device Marketing Authorization is the approval SFDA issues to a manufacturer allowing the device to be placed on the Saudi market. It is usually obtained through the manufacturer’s authorized representative in the Kingdom, and a device cannot be released for sale without a valid MDMA. It can be renewed ahead of expiry within the window SFDA sets.

Can used medical devices be imported into Saudi Arabia?

As a rule, no. SFDA’s requirements allow used devices only when they are imported for maintenance or refurbishment in the Kingdom and then re-exported, or when they return after maintenance, calibration, display or testing abroad. Each case needs the relevant permission.

How much shelf life must remain when medical devices arrive?

If the product’s total shelf life is under one year, at least 40% must remain at the port of entry. If it is over one year, at least seven months must remain, according to SFDA’s published requirements. Calculate it against the expected arrival date, not the ship date.

What is the GHAD system?

GHAD is SFDA’s electronic system used to apply for medical device importation licences and permissions in cases such as personal use, research, demonstration and chemicals classified as medical devices. Shipment release approval is requested separately through SFDA’s Faseh Services system and the FASAH platform.

Can a customs broker import medical devices without an importer licence?

No. A broker files the customs declaration and follows up the process, but cannot replace regulatory licences. To import devices for sale, the importer needs a valid establishment licence, the device needs an MDMA, and the manufacturer needs a licensed authorized representative in the Kingdom.

Sources

Regulations and procedures change. Check the official source before acting. This article is general information, not individual advice.